{"id":2498,"date":"2025-10-14T10:45:48","date_gmt":"2025-10-14T14:45:48","guid":{"rendered":"https:\/\/laboratorytesting.com\/?page_id=2498"},"modified":"2025-10-15T14:30:25","modified_gmt":"2025-10-15T18:30:25","slug":"investigational-procedures-for-volatile-organic-compounds-to-15","status":"publish","type":"page","link":"https:\/\/laboratorytesting.com\/es\/resources\/air-toxics\/investigational-procedures-for-volatile-organic-compounds-to-15\/","title":{"rendered":"Procedimientos de investigaci\u00f3n para compuestos org\u00e1nicos vol\u00e1tiles TO-15"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"2498\" class=\"elementor elementor-2498\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f0777b3 bg-four-corner-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0777b3\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4760a46\" data-id=\"4760a46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f2fe9f elementor-widget elementor-widget-heading\" data-id=\"4f2fe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedimientos de investigaci\u00f3n para <\/br>COV (TO-15)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60e3a7f elementor-widget elementor-widget-heading\" data-id=\"60e3a7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Desgasificaci\u00f3n de muestras a granel mediante c\u00e1mara ambiental, frascos de vidrio especiales y bolsas Tedlar.<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7912659 elementor-widget elementor-widget-text-editor\" data-id=\"7912659\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>EMSL utiliza diversas t\u00e9cnicas de c\u00e1maras ambientales para estudiar materiales sospechosos de desprender compuestos org\u00e1nicos vol\u00e1tiles (COV): las c\u00e1maras ambientales, los recipientes de espacio de cabeza con tapas especializadas y las bolsas de Tedlar son las m\u00e1s comunes.<\/p><p>Ofrecemos este servicio de investigaci\u00f3n para ayudar a nuestros clientes a aislar e identificar el origen de olores u otras emisiones vol\u00e1tiles procedentes de materiales de construcci\u00f3n o productos de mobiliario que se sospecha que causan efectos negativos en la calidad del aire interior.<\/p><p>El objetivo principal de estos estudios es identificar el o los compuestos presentes responsables del olor o del problema de calidad del aire interior. Las identificaciones cualitativas ayudar\u00e1n al usuario final de los datos a aislar la fuente del problema. Los aspectos cuantitativos de los datos son relativos y deben utilizarse en ese contexto.<\/p><p>Las incertidumbres relativas al material o al espacio estudiado dificultan la obtenci\u00f3n de resultados cuantitativos precisos. Las muestras pueden absorber compuestos durante el transporte y la manipulaci\u00f3n. Si no se seleccionan cuidadosamente, pueden producirse interacciones entre las muestras y los materiales de embalaje. La calidad del aire en los laboratorios es variable debido a las actividades profesionales en curso, que pueden liberar compuestos vol\u00e1tiles al ambiente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-e440b98 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e440b98\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3365ad5\" data-id=\"3365ad5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e05ff3e elementor-widget elementor-widget-text-editor\" data-id=\"e05ff3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La experiencia tambi\u00e9n nos indica que a menudo se encuentran peque\u00f1as cantidades de contaminantes, por ejemplo, en las superficies internas de las bolsas Tedlar que utilizamos para realizar pruebas en c\u00e1maras (bolsas) a peque\u00f1a escala.<\/p><p>Para minimizar estas variables en la medida de lo posible, se utilizan diversos medios para intentar reducir y cuantificar todos los niveles de fondo. El laboratorio espec\u00edfico donde se realizan los estudios de desgasificaci\u00f3n se encuentra bajo presi\u00f3n positiva para minimizar los COV en la corriente de aire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-05e5158\" data-id=\"05e5158\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-606c20e elementor-widget elementor-widget-image\" data-id=\"606c20e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"711\" height=\"354\" src=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/10\/investigational-procedures-image.png\" class=\"attachment-full size-full wp-image-2505\" alt=\"\" srcset=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/10\/investigational-procedures-image.png 711w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/10\/investigational-procedures-image-600x299.png 600w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/10\/investigational-procedures-image-300x149.png 300w\" sizes=\"(max-width: 711px) 100vw, 711px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e1db02 elementor-widget elementor-widget-text-editor\" data-id=\"7e1db02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Las bolsas Tedlar que utilizamos para realizar pruebas en c\u00e1mara (bolsa) a peque\u00f1a escala se enjuagan tres veces con nitr\u00f3geno de alta pureza antes de introducir las muestras. Los frascos de vidrio se purgan con nitr\u00f3geno durante un minuto antes de insertar la muestra.<\/p><p>Adem\u00e1s, nuestra peque\u00f1a c\u00e1mara ambiental (10 pies c\u00fabicos) cuenta con un filtro de carb\u00f3n activado en la entrada de aire y un cartucho de eliminaci\u00f3n de materia org\u00e1nica en l\u00ednea en la entrada de humedad.<\/p><p>Aun con todas estas precauciones, debemos tener en cuenta con precisi\u00f3n los niveles de fondo de los compuestos org\u00e1nicos. Parte de nuestro procedimiento para realizar estos estudios consiste en la preparaci\u00f3n de muestras en blanco o de referencia.<\/p><p>En nuestros informes de muestras en blanco, que se incluyen con los informes de sus muestras, podemos reportar niveles bajos de sustancias qu\u00edmicas comunes de laboratorio. No restamos ni excluimos los resultados de las muestras en blanco de sus resultados, con el fin de brindarle la mayor cantidad de informaci\u00f3n posible para que comprenda lo que puede estar ocurriendo en sus muestras a granel.<\/p><p>Si posteriormente se descubren compuestos tanto en la muestra como en la muestra de referencia, se puede realizar f\u00e1cilmente una correcci\u00f3n de fondo y reducir o eliminar el compuesto para su posterior an\u00e1lisis. Se presume que los compuestos encontrados en la muestra pero ausentes (o presentes en baja concentraci\u00f3n) en la muestra de referencia provienen predominantemente o exclusivamente de la muestra analizada.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Investigational Procedures for VOCs (TO-15) Off-gassing of bulk samples via Environmental Chamber, Specialty Glass Jars and Tedlar Bags EMSL uses various environmental chamber techniques to study materials suspected of off- gassing volatile organic compounds (VOCs): environmental chambers, head-space jars with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2502,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-2498","page","type-page","status-publish","hentry","slug-investigational-procedures-for-volatile-organic-compounds-to-15","even_post_id"],"_links":{"self":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/2498","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/comments?post=2498"}],"version-history":[{"count":14,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/2498\/revisions"}],"predecessor-version":[{"id":2610,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/2498\/revisions\/2610"}],"up":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/2502"}],"wp:attachment":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/media?parent=2498"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}