{"id":3260,"date":"2025-12-21T13:13:47","date_gmt":"2025-12-21T18:13:47","guid":{"rendered":"https:\/\/laboratorytesting.com\/?page_id=3260"},"modified":"2025-12-21T13:39:01","modified_gmt":"2025-12-21T18:39:01","slug":"heat-or-otherwise-altered-asbestos","status":"publish","type":"page","link":"https:\/\/laboratorytesting.com\/es\/resources\/asbestos\/heat-or-otherwise-altered-asbestos\/","title":{"rendered":"Amianto alterado por calor o de otro modo"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"3260\" class=\"elementor elementor-3260\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f0777b3 bg-four-corner-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0777b3\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4760a46\" data-id=\"4760a46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f2fe9f elementor-widget elementor-widget-heading\" data-id=\"4f2fe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Amianto alterado por calor o de otro modo<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b111717 elementor-widget elementor-widget-image\" data-id=\"b111717\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1600\" height=\"569\" src=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos.jpg\" class=\"attachment-full size-full wp-image-3262\" alt=\"\" srcset=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos.jpg 1600w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-600x213.jpg 600w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-300x107.jpg 300w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-1024x364.jpg 1024w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-768x273.jpg 768w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-1536x546.jpg 1536w\" sizes=\"(max-width: 1600px) 100vw, 1600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60e3a7f elementor-widget elementor-widget-heading\" data-id=\"60e3a7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Fondo<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7912659 elementor-widget elementor-widget-text-editor\" data-id=\"7912659\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Los materiales de construcci\u00f3n que contienen amianto pueden estar expuestos a altas temperaturas o a productos qu\u00edmicos. Las muestras de aislamiento de amianto utilizadas en calderas, hornos, tuber\u00edas de vapor, etc., se exponen a temperaturas muy elevadas durante periodos prolongados. Todo tipo de materiales de construcci\u00f3n pueden verse expuestos a temperaturas muy altas en incendios de cualquier tipo (incendios forestales, incendios en edificios, etc.). Esta exposici\u00f3n puede alterar el amianto presente, modificando, en mayor o menor medida, la estructura cristalina y la composici\u00f3n qu\u00edmica de las fibras. Otros factores, como la exposici\u00f3n a \u00e1cidos, tambi\u00e9n pueden tener efectos similares en las fibras de amianto, pero, sin duda, el ejemplo m\u00e1s com\u00fan es la alteraci\u00f3n del amianto por altas temperaturas.<\/p><p>Aunque los anf\u00edboles son comunes en este tipo de muestras, suele ser el crisotilo el que muestra el mayor grado de alteraci\u00f3n, ya que puede alterarse a una temperatura m\u00e1s baja en comparaci\u00f3n con la mayor\u00eda de los anf\u00edboles. En el caso del crisotilo, el \u00edndice de refracci\u00f3n (IR) y la difracci\u00f3n de electrones de \u00e1rea seleccionada (SAED) son los m\u00e1s afectados, puesto que esto se relaciona con la estructura cristalina de la fibra. La p\u00e9rdida de SAED en el crisotilo puede estar relacionada con la naturaleza m\u00e1s delicada de la estructura enrollada del crisotilo, donde los enlaces entre las estructuras enrolladas pueden estar m\u00e1s tensos y ser m\u00e1s propensos a romperse que en el cristal de anf\u00edbol, que es m\u00e1s duradero. Los anf\u00edboles tambi\u00e9n exhibir\u00e1n un cambio en el \u00edndice de refracci\u00f3n (IR), pero la SAED, medida mediante TEM, no suele verse afectada. Se necesita una alteraci\u00f3n m\u00e1s extrema para tener un efecto significativo en la SAED del anf\u00edbol. En todos los tipos de asbesto, calentar las fibras eventualmente provocar\u00e1 un aumento en sus IR. La alteraci\u00f3n qu\u00edmica tambi\u00e9n afecta al IR, pero en lugar de un aumento, normalmente disminuye el \u00edndice de refracci\u00f3n.<\/p><p>Otros cambios notables observados mediante PLM incluyen cambios en el signo de elongaci\u00f3n, el color de las fibras y la morfolog\u00eda. La crocidolita cambia su signo de elongaci\u00f3n, as\u00ed como el color de sus fibras. El crisotilo y la amosita tambi\u00e9n experimentan un cambio de color. Adem\u00e1s, la mayor\u00eda de los tipos de amianto se vuelven menos flexibles tras el calentamiento. Los haces de amianto pueden aparecer fusionados, adquiriendo una apariencia compacta. La crocidolita es tambi\u00e9n el primer tipo de amianto en mostrar alg\u00fan cambio; un breve periodo a 375 \u00b0C es suficiente para que comiencen a producirse.<\/p><p>En la microscop\u00eda electr\u00f3nica de transmisi\u00f3n (TEM), cuando el filamento de crisotilo parece estar da\u00f1ado o fusionado con fibras vecinas, es posible que no se puedan obtener los patrones de difracci\u00f3n de electrones de \u00e1rea seleccionada (SAED) para las fibras de crisotilo sospechosas y que se observen proporciones elementales alteradas, como una proporci\u00f3n Mg-Si inferior a la esperada.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e30bba elementor-widget elementor-widget-heading\" data-id=\"2e30bba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Pol\u00edtica de EMSL<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e1db02 elementor-widget elementor-widget-text-editor\" data-id=\"7e1db02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cuando encontramos una o varias fibras que se sospecha que son de amianto alterado porque las caracter\u00edsticas de identificaci\u00f3n (\u00edndice de refracci\u00f3n, color de la fibra, signo de elongaci\u00f3n, difracci\u00f3n, EDXA) est\u00e1n fuera del rango normal aceptable:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb9b2ca elementor-widget elementor-widget-heading\" data-id=\"eb9b2ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\">Para PLM:<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd06a6d elementor-widget elementor-widget-text-editor\" data-id=\"dd06a6d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>EMSL intentar\u00e1 identificar fibras o haces que parezcan ser amianto alterado. A menudo, los haces de fibras sospechosas se pueden separar, dejando propiedades \u00f3pticas inalteradas para su observaci\u00f3n. Cuando se determina que el material sospechoso es amianto con propiedades \u00f3pticas normales, la muestra pasa de &quot;no se detect\u00f3 amianto&quot; a al menos &quot;&lt;1%&quot;.\u201c<\/p><p>EMSL solo considerar\u00e1 como amianto la porci\u00f3n de las fibras sospechosas de asbesto que posean las propiedades \u00f3pticas correctas a efectos de los resultados finales. Es probable que en estas situaciones se detecte asbesto &lt;1%.<\/p><p>El hecho de que se detecten fibras de asbesto con valores de RI no significa que deban extrapolarse a toda la muestra de fibras &quot;anormales&quot;. Independientemente de si el resultado final es no detectable, \u2264 1% o &gt; 1%, es muy importante informar tanto la porci\u00f3n de asbesto alterado sospechoso como fibra no asbesto en los informes, como incluir un comentario en el informe de la muestra, como por ejemplo:<\/p><p><em>PLM: \u201cSe encontraron numerosas fibras con propiedades \u00f3pticas fuera de los l\u00edmites aceptables para el amianto regulado. Estas fibras son posiblemente fibras de amianto alteradas y no se incluyeron en la concentraci\u00f3n de la muestra de amianto.\u201d<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-83d850c elementor-widget elementor-widget-heading\" data-id=\"83d850c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\">Para TEM:<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5aa9c27 elementor-widget elementor-widget-text-editor\" data-id=\"5aa9c27\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El analista puede atribuir la qu\u00edmica o difracci\u00f3n anormal al amianto alterado por el calor, pero sin la observaci\u00f3n de las propiedades &quot;normales&quot;, a\u00fan no se puede afirmar que sea amianto. En el caso del crisotilo, un espectro con un pico de Mg inferior al esperado y una difracci\u00f3n de electrones de \u00e1rea seleccionada (SAED) ausente o deficiente, puede corresponder a una fibra que no sea amianto, como la sepiolita. Es m\u00e1s probable que los anf\u00edboles presenten una difracci\u00f3n SAED y una qu\u00edmica est\u00e1ndar, por lo que es menos probable que sea necesario realizar esta identificaci\u00f3n en su caso.<\/p><p>Al igual que con PLM, al intentar determinar un porcentaje estimado de amianto alterado en TEM, EMSL solo considerar\u00e1 como amianto, a efectos de los resultados finales, la porci\u00f3n de las fibras sospechosas de amianto que posean la difracci\u00f3n y\/o la composici\u00f3n qu\u00edmica correctas.<\/p><p>El hecho de que se detecten algunas fibras con la difracci\u00f3n de electrones de \u00e1rea seleccionada (SAED) y\/o la composici\u00f3n qu\u00edmica correctas no significa que se pueda realizar la identificaci\u00f3n de todas las fibras similares.<\/p><p><em>Microscop\u00eda electr\u00f3nica de transmisi\u00f3n (TEM): \u201cSe encontraron numerosas fibras con patrones de difracci\u00f3n y\/o composici\u00f3n qu\u00edmica fuera de los l\u00edmites aceptables del rango normal del amianto regulado. Estas fibras son posiblemente amianto alterado y no se incluyeron en la concentraci\u00f3n de la muestra de amianto.\u201d<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ed19b elementor-widget elementor-widget-text-editor\" data-id=\"c0ed19b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Pregunta:<\/strong> \u00bfEl amianto que ha sido alterado por calor o tratado qu\u00edmicamente sigue siendo amianto?<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb27b0c elementor-widget elementor-widget-text-editor\" data-id=\"eb27b0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Respuesta:<\/strong> Tanto si el an\u00e1lisis se realiza mediante microscop\u00eda de luz polarizada (PLM) como mediante microscop\u00eda electr\u00f3nica de transmisi\u00f3n (TEM), los m\u00e9todos proporcionan a los laboratorios criterios espec\u00edficos para determinar si una fibra se puede contabilizar como amianto. Para poder informar sobre la presencia de amianto, es necesario cumplir con estos criterios; por lo tanto, las fibras de amianto alteradas no se incluir\u00e1n en el porcentaje de amianto, incluso cuando se considere que circunstancias externas, como el calor, pueden ser la causa de la discrepancia.<\/p><p>Tambi\u00e9n es importante se\u00f1alar que, seg\u00fan la OSHA (y varias de sus contrapartes estatales), el amianto alterado se considera amianto, incluso si el m\u00e9todo no lo considera amianto cuantificable.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee4a285 elementor-widget elementor-widget-text-editor\" data-id=\"ee4a285\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si tiene alguna pregunta o necesita informaci\u00f3n adicional, \u00a1no dude en ponerse en contacto con nosotros!<br \/><a href=\"mailto:info@emsl.com\">info@emsl.com<\/a> | 800-220-3675<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Heat or Otherwise Altered Asbestos Background Building materials that contain asbestos may at times be exposed to high temperatures or chemicals. Asbestos insulation samples applied to boilers, furnaces, steam pipes, etc., are exposed to very high temperatures for extended periods [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2717,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-3260","page","type-page","status-publish","hentry","slug-heat-or-otherwise-altered-asbestos","even_post_id"],"_links":{"self":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/3260","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/comments?post=3260"}],"version-history":[{"count":7,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/3260\/revisions"}],"predecessor-version":[{"id":3269,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/3260\/revisions\/3269"}],"up":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/2717"}],"wp:attachment":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/media?parent=3260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}