{"id":4280,"date":"2026-03-08T06:22:14","date_gmt":"2026-03-08T10:22:14","guid":{"rendered":"https:\/\/laboratorytesting.com\/?page_id=4280"},"modified":"2026-03-08T06:34:24","modified_gmt":"2026-03-08T10:34:24","slug":"artificial-sweeteners-in-water-testing","status":"publish","type":"page","link":"https:\/\/laboratorytesting.com\/es\/resources\/food\/food-chemistry\/artificial-sweeteners-in-water-testing\/","title":{"rendered":"An\u00e1lisis de edulcorantes artificiales en el agua"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4280\" class=\"elementor elementor-4280\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f0777b3 bg-four-corner-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0777b3\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4760a46\" data-id=\"4760a46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f2fe9f elementor-widget elementor-widget-heading\" data-id=\"4f2fe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">An\u00e1lisis de edulcorantes artificiales en el agua<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b111717 elementor-widget elementor-widget-image\" data-id=\"b111717\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1440\" height=\"534\" src=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/03\/artificial-sweeteners.jpg\" class=\"attachment-full size-full wp-image-4282\" alt=\"\" srcset=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/03\/artificial-sweeteners.jpg 1440w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/03\/artificial-sweeteners-300x111.jpg 300w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/03\/artificial-sweeteners-1024x380.jpg 1024w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/03\/artificial-sweeteners-768x285.jpg 768w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/03\/artificial-sweeteners-600x223.jpg 600w\" sizes=\"(max-width: 1440px) 100vw, 1440px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7912659 elementor-widget elementor-widget-text-editor\" data-id=\"7912659\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Los edulcorantes artificiales se utilizan ampliamente en la elaboraci\u00f3n y producci\u00f3n de alimentos y bebidas. La mayor\u00eda de los procesos biol\u00f3gicos, incluido el sistema digestivo humano, no los metabolizan ni los alteran. Generalmente, se eliminan del cuerpo a trav\u00e9s de las heces. Las plantas de tratamiento de aguas residuales, que tratan estas aguas, son ineficaces para eliminar o degradar los edulcorantes. Debido a su estabilidad y alta solubilidad en agua, los edulcorantes son un buen indicador de la presencia de edulcorantes en las aguas residuales.<\/p><p>EMSL Analytical acepta muestras de agua para el an\u00e1lisis y la cuantificaci\u00f3n de determinados edulcorantes artificiales. Las muestras pueden enviarse a nuestra Divisi\u00f3n de Qu\u00edmica de Alimentos en Cinnaminson, Nueva Jersey, para su an\u00e1lisis.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-62c8479 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"62c8479\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-f4d64f7\" data-id=\"f4d64f7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3561055 elementor-widget elementor-widget-text-editor\" data-id=\"3561055\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>C\u00f3digo de prueba EMSL:<\/strong> Edulcorantes artificiales F639<br \/><strong>M\u00e9todo:<\/strong> M\u00e9todo desarrollado internamente<br \/><strong>Proceso de dar un t\u00edtulo:<\/strong> Ninguno, solo informaci\u00f3n<br \/><strong>Matrices:<\/strong> Aguas residuales, aguas subterr\u00e1neas, agua potable<\/p><p><strong>L\u00edmite de informes:<\/strong> 100 ng\/L<\/p><p><strong>Precio:<\/strong><br \/>$500 para un plazo de entrega de 2 semanas.<br \/>$750 para un plazo de entrega de 1 semana.<\/p><p><strong>Tama\u00f1o de muestra objetivo:<\/strong> 100 ml<br \/><strong>Muestra m\u00ednima:<\/strong> 25 ml<br \/><strong>M\u00e1ximo de muestra:<\/strong> 500 ml<\/p><p><strong>Contenedor de muestreo:<\/strong> Frasco de vidrio \u00e1mbar<br \/><strong>Requisitos de env\u00edo:<\/strong> Barco sobre hielo<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-2f6e09f\" data-id=\"2f6e09f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5cf7d97 elementor-widget elementor-widget-text-editor\" data-id=\"5cf7d97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Las muestras deben enviarse a:<\/strong><br \/>EMSL Analytical, Inc.<br \/>c\/o Divisi\u00f3n de Qu\u00edmica de los Alimentos<br \/>200 Ruta 130 Norte<br \/>Cinnaminson, NJ 08077<\/p><p><strong>Analitos que deben identificarse y cuantificarse:<\/strong><br \/>Acesulfamo K<br \/>Sucralosa<br \/>Sacarina<br \/>aspartamo<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Artificial Sweeteners in Water Testing Artificial sweeteners are used extensively in the making and production of food products and beverages. Sweeteners are not metabolized or altered by most biological processes, including the human digestive system. Artificial sweeteners are eliminated from [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":4288,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-4280","page","type-page","status-publish","hentry","slug-artificial-sweeteners-in-water-testing","even_post_id"],"_links":{"self":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/4280","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/comments?post=4280"}],"version-history":[{"count":4,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/4280\/revisions"}],"predecessor-version":[{"id":4285,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/4280\/revisions\/4285"}],"up":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/4288"}],"wp:attachment":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/media?parent=4280"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}