{"id":7829,"date":"2026-08-11T14:17:16","date_gmt":"2026-08-11T18:17:16","guid":{"rendered":"https:\/\/laboratorytesting.com\/?page_id=7829"},"modified":"2026-08-11T14:27:11","modified_gmt":"2026-08-11T18:27:11","slug":"combustion-by-products-2025","status":"publish","type":"page","link":"https:\/\/laboratorytesting.com\/es\/resources\/materials-science\/combustion-by-products-2025\/","title":{"rendered":"Subproductos de la combusti\u00f3n 2025"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"7829\" class=\"elementor elementor-7829\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f0777b3 bg-four-corner-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0777b3\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4760a46\" data-id=\"4760a46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f2fe9f elementor-widget elementor-widget-heading\" data-id=\"4f2fe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Subproductos de la combusti\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13cae54 elementor-widget elementor-widget-image\" data-id=\"13cae54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1440\" height=\"506\" src=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/combustion-by-products.jpg\" class=\"attachment-full size-full wp-image-5614\" alt=\"\" srcset=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/combustion-by-products.jpg 1440w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/combustion-by-products-300x105.jpg 300w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/combustion-by-products-1024x360.jpg 1024w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/combustion-by-products-768x270.jpg 768w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/combustion-by-products-600x211.jpg 600w\" sizes=\"(max-width: 1440px) 100vw, 1440px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06f0ed1 elementor-widget elementor-widget-heading\" data-id=\"06f0ed1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Prop\u00f3sito de la prueba<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c6595c elementor-widget elementor-widget-text-editor\" data-id=\"3c6595c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Esta prueba est\u00e1 dise\u00f1ada para analizar los residuos de incendios y detectar la presencia de analitos de inter\u00e9s (carbonilla, holl\u00edn y ceniza). Los resultados ofrecen al cliente informaci\u00f3n valiosa sobre la magnitud de los da\u00f1os causados por un incendio en una ubicaci\u00f3n (residencial, industrial o forestal). Estos resultados pueden utilizarse para evaluar la limpieza y\/o para tramitar reclamaciones de seguros.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8db31f elementor-widget elementor-widget-heading\" data-id=\"a8db31f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Muestreo<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-adef3e6 elementor-widget elementor-widget-text-editor\" data-id=\"adef3e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Muestreo de superficie:<\/strong><\/p><ul><li>Toallitas desinfectantes con alcohol (superficies recomendadas: pantallas de televisores y ordenadores, superficies de pl\u00e1stico, muebles, ventanas, espejos, superficies internas de frigor\u00edficos; evitar superficies pintadas).<\/li><li>Microvac\u00edo: casetes MCE de 25 mm con tama\u00f1o de poro de 0,45 micras o 0,8 micras (superficies recomendadas: \u00e1reas principales de estar, desde la parte superior del marco de la puerta interior, marco de la ventana, desde las esquinas de los pisos, rieles de las puertas, \u00e1reas del \u00e1tico).<\/li><li>Cintas adhesivas (superficies recomendadas: las mismas que para las toallitas con alcohol)*<\/li><\/ul><p><strong>Muestreo de aire:<\/strong><\/p><ul><li>Casetes de PVC pre-pesados (solo para NIOSH 5000)<\/li><li>Casetes Zefon CSI*<\/li><li>Celdas de aire Zefon*<\/li><li>Cassettes MCE de 25 mm con tama\u00f1o de poro de 0,45 micras; Caudal de 0,5 a 16 L\/min, Volumen m\u00ednimo 400*<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-934a5c0 tp-shortcode elementor-widget elementor-widget-shortcode\" data-id=\"934a5c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-108\" class=\"tablepress tablepress-id-108 tp-text-center tp-no-border tp-y-padding-zero tp-border-all-around-table tp-head-vertical-top tp-combustion-by-products tp-mat-sci-color-scheme\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Combusti\u00f3n<br \/>\nPor productos<\/th><th class=\"column-2\">Equipo\/Prop\u00f3sito<\/th><th class=\"column-3\">1 d\u00eda<\/th><th class=\"column-4\">2 d\u00edas<\/th><th class=\"column-5\">3 d\u00edas<\/th><th class=\"column-6\">4 d\u00edas<\/th><th class=\"column-7\">1 semana<\/th><th class=\"column-8\">2 semanas<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">NIOSH 5000 (aire)<\/td><td class=\"column-2\">An\u00e1lisis gravim\u00e9trico \u00fanicamente para<br \/>\nNegro carb\u00f3n<\/td><td class=\"column-3\">$307<\/td><td class=\"column-4\">$232<\/td><td class=\"column-5\">$183<\/td><td class=\"column-6\">$150<\/td><td class=\"column-7\">$127<\/td><td class=\"column-8\">$84<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">NIOSH 5000 con<br \/>\nConfirmaci\u00f3n (a\u00e9rea)<\/td><td class=\"column-2\">Incluye confirmaci\u00f3n por TEM.<\/td><td class=\"column-3\">Llamar<\/td><td class=\"column-4\">$1,314<\/td><td class=\"column-5\">$1,049<\/td><td class=\"column-6\">$861<\/td><td class=\"column-7\">$717<\/td><td class=\"column-8\">$478<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Combusti\u00f3n por-<br \/>\nProductos - Nivel 1<\/td><td class=\"column-2\">Carbonizaci\u00f3n + Holl\u00edn (presunto) + Ceniza<\/td><td class=\"column-3\">Llamar<\/td><td class=\"column-4\">$550<\/td><td class=\"column-5\">$439<\/td><td class=\"column-6\">$358<\/td><td class=\"column-7\">$300<\/td><td class=\"column-8\">$199<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Combusti\u00f3n por-<br \/>\nProductos - Nivel 1 PLUS<\/td><td class=\"column-2\">Carbonizaci\u00f3n + Holl\u00edn (presunto) + Ceniza<br \/>\n+ Polvo ambiental<\/td><td class=\"column-3\">$847<\/td><td class=\"column-4\">$664<\/td><td class=\"column-5\">$532<\/td><td class=\"column-6\">$435<\/td><td class=\"column-7\">$362<\/td><td class=\"column-8\">$242<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Combusti\u00f3n por-<br \/>\nProductos - Nivel 2<\/td><td class=\"column-2\">Carbonizaci\u00f3n + Holl\u00edn (confirmaci\u00f3n) + Ceniza<\/td><td class=\"column-3\">Llamar<\/td><td class=\"column-4\">$1,314<\/td><td class=\"column-5\">$1,049<\/td><td class=\"column-6\">$861<\/td><td class=\"column-7\">$717<\/td><td class=\"column-8\">$478<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Combusti\u00f3n por-<br \/>\nProductos - Nivel 3<\/td><td class=\"column-2\">Nivel 2 + ID de part\u00edcula com\u00fan<\/td><td class=\"column-3\">Llamar<\/td><td class=\"column-4\">$1,401<\/td><td class=\"column-5\">$1,122<\/td><td class=\"column-6\">$917<\/td><td class=\"column-7\">$763<\/td><td class=\"column-8\">$511<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Combusti\u00f3n por-<br \/>\nProductos - Nivel 4<\/td><td class=\"column-2\">Nivel 3 + SEM\/EDX + pH<br \/>\n(corrosividad)<\/td><td class=\"column-3\">Llamar<\/td><td class=\"column-4\">$1,609<\/td><td class=\"column-5\">$1,288<\/td><td class=\"column-6\">$1,054<\/td><td class=\"column-7\">$879<\/td><td class=\"column-8\">$586<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Examen de detecci\u00f3n (solo P\/A)<\/td><td class=\"column-2\">Carbonizaci\u00f3n + Holl\u00edn (presunto) + Ceniza<\/td><td class=\"column-3\">$307<\/td><td class=\"column-4\">$232<\/td><td class=\"column-5\">$183<\/td><td class=\"column-6\">$150<\/td><td class=\"column-7\">$127<\/td><td class=\"column-8\">$84<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-108 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-565176d elementor-widget elementor-widget-text-editor\" data-id=\"565176d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>*Los casetes Tape Lift, Zefon CSI y Zefon Air-o-cell solo son aceptables para pruebas de presencia\/ausencia o de nivel 1.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Combustion By-Products Purpose of Test This test is designed for analysis of fire residues for presence of analytes of interest (char, black carbon\/soot and ash). The results of this test offer the client valuable information related to the extent of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":5604,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-7829","page","type-page","status-publish","hentry","slug-combustion-by-products-2025","odd_post_id"],"_links":{"self":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/7829","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/comments?post=7829"}],"version-history":[{"count":7,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/7829\/revisions"}],"predecessor-version":[{"id":7837,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/7829\/revisions\/7837"}],"up":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/pages\/5604"}],"wp:attachment":[{"href":"https:\/\/laboratorytesting.com\/es\/wp-json\/wp\/v2\/media?parent=7829"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}