{"id":2498,"date":"2025-10-14T10:45:48","date_gmt":"2025-10-14T14:45:48","guid":{"rendered":"https:\/\/laboratorytesting.com\/?page_id=2498"},"modified":"2025-10-15T14:30:25","modified_gmt":"2025-10-15T18:30:25","slug":"investigational-procedures-for-volatile-organic-compounds-to-15","status":"publish","type":"page","link":"https:\/\/laboratorytesting.com\/fr\/resources\/air-toxics\/investigational-procedures-for-volatile-organic-compounds-to-15\/","title":{"rendered":"Proc\u00e9dures d&#039;investigation pour les compos\u00e9s organiques volatils TO-15"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"2498\" class=\"elementor elementor-2498\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f0777b3 bg-four-corner-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0777b3\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4760a46\" data-id=\"4760a46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f2fe9f elementor-widget elementor-widget-heading\" data-id=\"4f2fe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Proc\u00e9dures d&#039;investigation pour <\/br>COV (TO-15)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60e3a7f elementor-widget elementor-widget-heading\" data-id=\"60e3a7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">D\u00e9gazage d&#039;\u00e9chantillons en vrac via une chambre environnementale, des bocaux en verre sp\u00e9ciaux et des sacs Tedlar.<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7912659 elementor-widget elementor-widget-text-editor\" data-id=\"7912659\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>EMSL utilise diverses techniques de chambres environnementales pour \u00e9tudier les mat\u00e9riaux soup\u00e7onn\u00e9s de d\u00e9gager des compos\u00e9s organiques volatils (COV) : les chambres environnementales, les bocaux \u00e0 espace de t\u00eate avec couvercles sp\u00e9cialis\u00e9s et les sacs Tedlar sont les plus courants.<\/p><p>Nous proposons ce service d&#039;investigation pour aider nos clients \u00e0 isoler et identifier la source des odeurs ou autres \u00e9missions volatiles provenant de mat\u00e9riaux de construction ou de produits d&#039;ameublement soup\u00e7onn\u00e9s d&#039;avoir des effets n\u00e9fastes sur la qualit\u00e9 de l&#039;air int\u00e9rieur.<\/p><p>L&#039;objectif principal de ces \u00e9tudes est d&#039;identifier le ou les compos\u00e9s responsables des odeurs ou des probl\u00e8mes de qualit\u00e9 de l&#039;air int\u00e9rieur. L&#039;identification qualitative des donn\u00e9es aidera l&#039;utilisateur final \u00e0 isoler la source du probl\u00e8me. Les donn\u00e9es quantitatives ne sont que relatives et doivent \u00eatre interpr\u00e9t\u00e9es dans ce contexte.<\/p><p>Les incertitudes li\u00e9es au mat\u00e9riau et\/ou \u00e0 l&#039;espace \u00e9tudi\u00e9s font que l&#039;obtention de r\u00e9sultats v\u00e9ritablement quantitatifs reste souvent difficile. Les \u00e9chantillons peuvent absorber des compos\u00e9s lors du transport et de la manipulation. Des interactions peuvent survenir entre les \u00e9chantillons et les mat\u00e9riaux d&#039;emballage si ces derniers ne sont pas soigneusement s\u00e9lectionn\u00e9s. La qualit\u00e9 de l&#039;air dans les laboratoires est variable en raison des activit\u00e9s professionnelles qui peuvent lib\u00e9rer des compos\u00e9s volatils.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-e440b98 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e440b98\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3365ad5\" data-id=\"3365ad5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e05ff3e elementor-widget elementor-widget-text-editor\" data-id=\"e05ff3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u2019exp\u00e9rience nous montre \u00e9galement que de petites quantit\u00e9s de contaminants sont souvent pr\u00e9sentes, par exemple, sur les surfaces int\u00e9rieures des sacs Tedlar que nous utilisons pour effectuer des tests en chambre (sac) \u00e0 petite \u00e9chelle.<\/p><p>Afin de minimiser ces variables autant que possible, divers moyens sont utilis\u00e9s pour tenter de r\u00e9duire et de quantifier tous les niveaux de fond. Le laboratoire sp\u00e9cifique o\u00f9 sont r\u00e9alis\u00e9es les \u00e9tudes de d\u00e9gazage est plac\u00e9 sous pression positive afin de minimiser la concentration de COV dans le flux d&#039;air.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-05e5158\" data-id=\"05e5158\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-606c20e elementor-widget elementor-widget-image\" data-id=\"606c20e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"711\" height=\"354\" src=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/10\/investigational-procedures-image.png\" class=\"attachment-full size-full wp-image-2505\" alt=\"\" srcset=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/10\/investigational-procedures-image.png 711w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/10\/investigational-procedures-image-600x299.png 600w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/10\/investigational-procedures-image-300x149.png 300w\" sizes=\"(max-width: 711px) 100vw, 711px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e1db02 elementor-widget elementor-widget-text-editor\" data-id=\"7e1db02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les sacs Tedlar utilis\u00e9s pour les essais en chambre (sac) \u00e0 petite \u00e9chelle sont rinc\u00e9s trois fois \u00e0 l&#039;azote de haute puret\u00e9 avant le chargement des \u00e9chantillons. Les bocaux en verre sont purg\u00e9s \u00e0 l&#039;azote pendant une minute avant l&#039;insertion de l&#039;\u00e9chantillon.<\/p><p>De plus, notre petite chambre environnementale (10 pi3) est \u00e9quip\u00e9e d&#039;un filtre \u00e0 charbon sur l&#039;entr\u00e9e d&#039;air et d&#039;une cartouche d&#039;\u00e9limination organique en ligne sur l&#039;entr\u00e9e d&#039;humidit\u00e9.<\/p><p>Malgr\u00e9 toutes ces pr\u00e9cautions, il est indispensable de tenir compte avec pr\u00e9cision des concentrations de fond de compos\u00e9s organiques. La pr\u00e9paration d&#039;\u00e9chantillons t\u00e9moins ou de fond fait partie int\u00e9grante de notre protocole pour la r\u00e9alisation de ces \u00e9tudes.<\/p><p>Nos rapports de r\u00e9f\u00e9rence, joints \u00e0 vos analyses d&#039;\u00e9chantillons, peuvent indiquer de faibles concentrations de produits chimiques de laboratoire courants. Nous ne soustrayons ni n&#039;excluons les r\u00e9sultats des \u00e9chantillons de r\u00e9f\u00e9rence de vos analyses, afin de vous fournir un maximum d&#039;informations pour comprendre ce qui se passe dans vos \u00e9chantillons en vrac.<\/p><p>Si des compos\u00e9s sont ult\u00e9rieurement d\u00e9tect\u00e9s \u00e0 la fois dans l&#039;\u00e9chantillon de mat\u00e9riau et dans le blanc, une correction du bruit de fond peut \u00eatre facilement effectu\u00e9e, et le compos\u00e9 ainsi d\u00e9tect\u00e9 ou \u00e9limin\u00e9 de l&#039;analyse. Les compos\u00e9s pr\u00e9sents dans l&#039;\u00e9chantillon de mat\u00e9riau mais absents (ou faiblement pr\u00e9sents) dans le blanc sont consid\u00e9r\u00e9s comme provenant principalement ou exclusivement de l&#039;\u00e9chantillon de mat\u00e9riau soumis.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Investigational Procedures for VOCs (TO-15) Off-gassing of bulk samples via Environmental Chamber, Specialty Glass Jars and Tedlar Bags EMSL uses various environmental chamber techniques to study materials suspected of off- gassing volatile organic compounds (VOCs): environmental chambers, head-space jars with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2502,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-2498","page","type-page","status-publish","hentry","slug-investigational-procedures-for-volatile-organic-compounds-to-15","even_post_id"],"_links":{"self":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/2498","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/comments?post=2498"}],"version-history":[{"count":14,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/2498\/revisions"}],"predecessor-version":[{"id":2610,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/2498\/revisions\/2610"}],"up":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/2502"}],"wp:attachment":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/media?parent=2498"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}