{"id":3260,"date":"2025-12-21T13:13:47","date_gmt":"2025-12-21T18:13:47","guid":{"rendered":"https:\/\/laboratorytesting.com\/?page_id=3260"},"modified":"2025-12-21T13:39:01","modified_gmt":"2025-12-21T18:39:01","slug":"heat-or-otherwise-altered-asbestos","status":"publish","type":"page","link":"https:\/\/laboratorytesting.com\/fr\/resources\/asbestos\/heat-or-otherwise-altered-asbestos\/","title":{"rendered":"Amiante alt\u00e9r\u00e9e par la chaleur ou autrement"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"3260\" class=\"elementor elementor-3260\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f0777b3 bg-four-corner-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0777b3\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4760a46\" data-id=\"4760a46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f2fe9f elementor-widget elementor-widget-heading\" data-id=\"4f2fe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Amiante alt\u00e9r\u00e9e par la chaleur ou autrement<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b111717 elementor-widget elementor-widget-image\" data-id=\"b111717\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1600\" height=\"569\" src=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos.jpg\" class=\"attachment-full size-full wp-image-3262\" alt=\"\" srcset=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos.jpg 1600w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-600x213.jpg 600w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-300x107.jpg 300w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-1024x364.jpg 1024w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-768x273.jpg 768w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2025\/12\/heat-or-otherwise-altered-asbestos-1536x546.jpg 1536w\" sizes=\"(max-width: 1600px) 100vw, 1600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60e3a7f elementor-widget elementor-widget-heading\" data-id=\"60e3a7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Arri\u00e8re-plan<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7912659 elementor-widget elementor-widget-text-editor\" data-id=\"7912659\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les mat\u00e9riaux de construction contenant de l&#039;amiante peuvent \u00eatre expos\u00e9s \u00e0 des temp\u00e9ratures \u00e9lev\u00e9es ou \u00e0 des produits chimiques. Les isolants en amiante utilis\u00e9s sur les chaudi\u00e8res, les fours, les conduites de vapeur, etc., sont expos\u00e9s \u00e0 des temp\u00e9ratures tr\u00e8s \u00e9lev\u00e9es pendant de longues p\u00e9riodes. Tous les types de mat\u00e9riaux de construction peuvent \u00eatre expos\u00e9s \u00e0 des temp\u00e9ratures tr\u00e8s \u00e9lev\u00e9es lors d&#039;incendies de toute nature (feux de for\u00eat, incendies de b\u00e2timents, etc.). Cette exposition peut alt\u00e9rer l&#039;amiante, modifiant plus ou moins la structure cristalline et la composition chimique des fibres. D&#039;autres facteurs, comme l&#039;exposition \u00e0 des acides, peuvent \u00e9galement avoir des effets similaires sur les fibres d&#039;amiante, mais l&#039;exemple le plus courant reste l&#039;alt\u00e9ration de l&#039;amiante par les hautes temp\u00e9ratures.<\/p><p>Bien que les amphiboles soient courantes dans ce type d&#039;\u00e9chantillons, c&#039;est g\u00e9n\u00e9ralement le chrysotile qui pr\u00e9sente le plus grand degr\u00e9 d&#039;alt\u00e9ration, car il peut \u00eatre alt\u00e9r\u00e9 \u00e0 une temp\u00e9rature plus basse que la plupart des amphiboles. Pour le chrysotile, l&#039;indice de r\u00e9fraction (IR) et la diffraction \u00e9lectronique en aire s\u00e9lectionn\u00e9e (SAED) sont les plus affect\u00e9s, car ils sont li\u00e9s \u00e0 la structure cristalline de la fibre. La perte de SAED dans le chrysotile peut \u00eatre li\u00e9e \u00e0 la nature plus fragile de sa structure enroul\u00e9e, o\u00f9 les liaisons entre les spires sont potentiellement plus sollicit\u00e9es et susceptibles de se rompre que dans le cristal d&#039;amphibole, plus r\u00e9sistant. Les amphiboles pr\u00e9sentent \u00e9galement une variation d&#039;indice de r\u00e9fraction (IR), mais la SAED, mesur\u00e9e par MET, n&#039;est g\u00e9n\u00e9ralement pas affect\u00e9e. Une alt\u00e9ration plus importante est n\u00e9cessaire pour avoir un effet significatif sur la SAED des amphiboles. Pour tous les types d&#039;amiante, le chauffage des fibres entra\u00eene \u00e0 terme une augmentation de leur IR. L&#039;alt\u00e9ration chimique affecte \u00e9galement l&#039;IR, mais au lieu de l&#039;augmenter, elle le diminue g\u00e9n\u00e9ralement.<\/p><p>Parmi les autres changements notables observ\u00e9s par microscopie optique \u00e0 lumi\u00e8re polaris\u00e9e (PLM), on note des modifications du signe d&#039;allongement, de la couleur des fibres et de leur morphologie. La crocidolite modifie son signe d&#039;allongement ainsi que la couleur de ses fibres. Le chrysotile et l&#039;amosite subissent \u00e9galement un changement de couleur. De plus, la plupart des types d&#039;amiante perdent en flexibilit\u00e9 apr\u00e8s chauffage. Les faisceaux d&#039;amiante peuvent para\u00eetre \u201c\u00a0fusionn\u00e9s\u00a0\u201d, leur donnant un aspect massif. La crocidolite est \u00e9galement le premier de ces types \u00e0 pr\u00e9senter des modifications\u00a0; une courte exposition \u00e0 375\u00a0\u00b0C suffit \u00e0 amorcer ces changements.<\/p><p>En MET, lorsque le rouleau de chrysotile semble endommag\u00e9 ou fusionn\u00e9 avec les fibres voisines, les diagrammes SAED des fibres de chrysotile suspectes peuvent ne pas \u00eatre accessibles et des rapports \u00e9l\u00e9mentaires alt\u00e9r\u00e9s, tels qu&#039;un rapport Mg-Si inf\u00e9rieur aux pr\u00e9visions, peuvent \u00eatre observ\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e30bba elementor-widget elementor-widget-heading\" data-id=\"2e30bba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Politique d&#039;EMSL<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e1db02 elementor-widget elementor-widget-text-editor\" data-id=\"7e1db02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Lorsque nous rencontrons une ou plusieurs fibres suspect\u00e9es d&#039;\u00eatre de l&#039;amiante alt\u00e9r\u00e9e parce que leurs caract\u00e9ristiques d&#039;identification (indice de r\u00e9fraction, couleur de la fibre, signe d&#039;allongement, diffraction, EDXA) sont en dehors de la plage normale acceptable\u00a0:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb9b2ca elementor-widget elementor-widget-heading\" data-id=\"eb9b2ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\">Pour le PLM\u00a0:<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd06a6d elementor-widget elementor-widget-text-editor\" data-id=\"dd06a6d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>EMSL tentera d&#039;identifier les fibres ou faisceaux qui semblent \u00eatre de l&#039;amiante alt\u00e9r\u00e9e. Souvent, les faisceaux de fibres suspectes peuvent \u00eatre d\u00e9membr\u00e9s, ce qui permet d&#039;observer leurs propri\u00e9t\u00e9s optiques intactes. Si le mat\u00e9riau suspect est identifi\u00e9 comme \u00e9tant de l&#039;amiante aux propri\u00e9t\u00e9s optiques normales, l&#039;\u00e9chantillon passe de la mention \u201c\u00a0amiante non d\u00e9tect\u00e9e\u00a0\u201d \u00e0 \u201c\u00a0au moins &lt;1%\u00a0\u201d.\u201d<\/p><p>Pour les r\u00e9sultats finaux, EMSL ne consid\u00e9rera comme amiante que la portion des fibres suspectes pr\u00e9sentant les propri\u00e9t\u00e9s optiques requises. Il est probable que de l&#039;amiante &lt;1% soit signal\u00e9e dans ces situations.<\/p><p>La d\u00e9tection de fibres d&#039;amiante pr\u00e9sentant des valeurs d&#039;indice de r\u00e9fraction (IR) ne signifie pas qu&#039;il faille g\u00e9n\u00e9raliser ces r\u00e9sultats \u00e0 l&#039;ensemble des fibres \u201c anormales \u201d de l&#039;\u00e9chantillon. Que le r\u00e9sultat final soit une absence de d\u00e9tection, une valeur d&#039;IR \u2264 1% ou &gt; 1%, il est essentiel de mentionner dans les rapports la proportion de fibres d&#039;amiante potentiellement alt\u00e9r\u00e9es consid\u00e9r\u00e9es comme non amiant\u00e9es, et d&#039;ajouter un commentaire au rapport d&#039;analyse, par exemple\u00a0:<\/p><p><em>PLM\u00a0: \u201c\u00a0De nombreuses fibres pr\u00e9sentant des propri\u00e9t\u00e9s optiques hors des limites acceptables pour l\u2019amiante r\u00e9glement\u00e9e ont \u00e9t\u00e9 trouv\u00e9es. Il s\u2019agit probablement de fibres d\u2019amiante alt\u00e9r\u00e9es qui n\u2019ont pas \u00e9t\u00e9 prises en compte dans la concentration de l\u2019\u00e9chantillon d\u2019amiante.\u00a0\u201d<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-83d850c elementor-widget elementor-widget-heading\" data-id=\"83d850c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\">Pour le MET\u00a0:<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5aa9c27 elementor-widget elementor-widget-text-editor\" data-id=\"5aa9c27\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L&#039;analyste peut attribuer les anomalies chimiques ou de diffraction \u00e0 de l&#039;amiante alt\u00e9r\u00e9e par la chaleur, mais sans l&#039;observation des propri\u00e9t\u00e9s \u201c\u00a0normales\u00a0\u201d, il est impossible de confirmer qu&#039;il s&#039;agit d&#039;amiante. Dans le cas du chrysotile, un spectre pr\u00e9sentant un pic de magn\u00e9sium plus faible que pr\u00e9vu et une diffraction \u00e9lectronique en aire s\u00e9lectionn\u00e9e (SAED) absente ou de mauvaise qualit\u00e9 peut indiquer la pr\u00e9sence d&#039;une fibre non amiant\u00e9e, comme la s\u00e9piolite. Les amphiboles pr\u00e9sentent g\u00e9n\u00e9ralement une diffraction SAED et une composition chimique standard\u00a0; il est donc moins probable que cette identification soit n\u00e9cessaire pour elles.<\/p><p>Comme pour la PLM, lorsqu&#039;on tente de d\u00e9terminer un pourcentage estim\u00e9 d&#039;amiante alt\u00e9r\u00e9e en MET, l&#039;EMSL ne prendra en compte que la portion des fibres d&#039;amiante suspect\u00e9es qui poss\u00e8dent une diffraction et\/ou une chimie correctes pour \u00eatre consid\u00e9r\u00e9es comme de l&#039;amiante aux fins des r\u00e9sultats finaux.<\/p><p>Le fait que certaines fibres pr\u00e9sentant une diffraction \u00e9lectronique \u00e0 aire s\u00e9lectionn\u00e9e (SAED) et\/ou une composition chimique correctes soient d\u00e9tect\u00e9es ne signifie pas que l&#039;identification puisse \u00eatre faite pour toutes les fibres similaires.<\/p><p><em>MET\u00a0: \u201c\u00a0De nombreuses fibres pr\u00e9sentaient des diagrammes de diffraction et\/ou une composition chimique hors des limites acceptables pour l\u2019amiante r\u00e9glement\u00e9e. Ces fibres sont probablement de l\u2019amiante alt\u00e9r\u00e9e et n\u2019ont pas \u00e9t\u00e9 prises en compte dans la concentration de l\u2019\u00e9chantillon d\u2019amiante.\u00a0\u201d<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ed19b elementor-widget elementor-widget-text-editor\" data-id=\"c0ed19b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Question:<\/strong> L&#039;amiante ayant subi un traitement thermique ou chimique est-elle toujours de l&#039;amiante ?<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb27b0c elementor-widget elementor-widget-text-editor\" data-id=\"eb27b0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>R\u00e9pondre:<\/strong> Que l&#039;analyse soit r\u00e9alis\u00e9e par microscopie optique polaris\u00e9e (PLM) ou par microscopie \u00e9lectronique \u00e0 transmission (TEM), les m\u00e9thodes fournissent aux laboratoires des crit\u00e8res pr\u00e9cis pour d\u00e9terminer si une fibre peut \u00eatre comptabilis\u00e9e comme amiante. Pour que la pr\u00e9sence d&#039;amiante soit d\u00e9clar\u00e9e, ces crit\u00e8res doivent \u00eatre respect\u00e9s\u00a0; par cons\u00e9quent, les fibres d&#039;amiante alt\u00e9r\u00e9es ne seront pas prises en compte dans le calcul du pourcentage d&#039;amiante, m\u00eame si l&#039;on soup\u00e7onne que des facteurs externes, tels que la chaleur, puissent \u00eatre \u00e0 l&#039;origine de l&#039;\u00e9cart.<\/p><p>Il est \u00e9galement important de noter que, selon l&#039;OSHA (et un certain nombre de ses homologues \u00e9tatiques), l&#039;amiante modifi\u00e9e est consid\u00e9r\u00e9e comme de l&#039;amiante, m\u00eame si elle n&#039;est pas consid\u00e9r\u00e9e comme de l&#039;amiante comptabilisable selon la m\u00e9thode.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee4a285 elementor-widget elementor-widget-text-editor\" data-id=\"ee4a285\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si vous avez des questions ou si vous souhaitez obtenir des informations compl\u00e9mentaires, n&#039;h\u00e9sitez pas \u00e0 nous contacter !<br \/><a href=\"mailto:info@emsl.com\">info@emsl.com<\/a> | 800-220-3675<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Heat or Otherwise Altered Asbestos Background Building materials that contain asbestos may at times be exposed to high temperatures or chemicals. Asbestos insulation samples applied to boilers, furnaces, steam pipes, etc., are exposed to very high temperatures for extended periods [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2717,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-3260","page","type-page","status-publish","hentry","slug-heat-or-otherwise-altered-asbestos","even_post_id"],"_links":{"self":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/3260","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/comments?post=3260"}],"version-history":[{"count":7,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/3260\/revisions"}],"predecessor-version":[{"id":3269,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/3260\/revisions\/3269"}],"up":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/2717"}],"wp:attachment":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/media?parent=3260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}