{"id":5653,"date":"2026-04-21T02:21:27","date_gmt":"2026-04-21T06:21:27","guid":{"rendered":"https:\/\/laboratorytesting.com\/?page_id=5653"},"modified":"2026-04-21T02:44:27","modified_gmt":"2026-04-21T06:44:27","slug":"lithium-ion-battery-fire-residues-analysis","status":"publish","type":"page","link":"https:\/\/laboratorytesting.com\/fr\/resources\/materials-science\/lithium-ion-battery-fire-residues-analysis\/","title":{"rendered":"Analyse des r\u00e9sidus d&#039;incendie des batteries lithium-ion"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"5653\" class=\"elementor elementor-5653\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f0777b3 bg-four-corner-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0777b3\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4760a46\" data-id=\"4760a46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f2fe9f elementor-widget elementor-widget-heading\" data-id=\"4f2fe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Lithium-Ion Battery Fire Residues Analysis<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13cae54 elementor-widget elementor-widget-image\" data-id=\"13cae54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1440\" height=\"504\" src=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lithium-ion-battery-fire-residues-analysis.jpg\" class=\"attachment-full size-full wp-image-5658\" alt=\"\" srcset=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lithium-ion-battery-fire-residues-analysis.jpg 1440w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lithium-ion-battery-fire-residues-analysis-300x105.jpg 300w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lithium-ion-battery-fire-residues-analysis-1024x358.jpg 1024w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lithium-ion-battery-fire-residues-analysis-768x269.jpg 768w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lithium-ion-battery-fire-residues-analysis-600x210.jpg 600w\" sizes=\"(max-width: 1440px) 100vw, 1440px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c6595c list-left-align elementor-widget elementor-widget-text-editor\" data-id=\"3c6595c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>EMSL Analytical, Inc. provides testing for lithium-ion battery fire residues in the Materials Science Laboratory. The major chemical components in lithium-ion batteries (LIB\u2019s) are:<\/p><ul><li>Lithium combined with a metal oxide <em>(for cathode)<\/em><ul><li>Lithium + Cobalt Oxide<\/li><li>Lithium + [Nickel + Cobalt+ Aluminum] Oxides<\/li><li>Lithium + [Nickel + Cobalt+ Manganese] Oxides<\/li><li>Lithium + [Nickel + Cobalt+ Manganese+ Aluminum] Oxides<\/li><\/ul><\/li><li>Lithium + [Aluminum + Titanium] Phosphate <em>(alternative for cathode)<\/em><\/li><li>Silicon-Carbon or Graphite <em>(for anode)<\/em><\/li><li>Lithium Hexafluorophosphate LiPF6 <em>(electrolyte)<\/em><\/li><li>Fluoropolymers <em>(as binders)<\/em><\/li><li>Polymers <em>(as separator)<\/em><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-934a5c0 tp-shortcode elementor-widget elementor-widget-shortcode\" data-id=\"934a5c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-52\" class=\"tablepress tablepress-id-52 tp-all-border tp-small-padding tp-y-padding-zero tp-mat-sci-color-scheme tp-text-center tp-left-align-list tp-lithium-ion-battery-fire-residues-analysis\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Analyte<\/th><th class=\"column-2\">Method<\/th><th class=\"column-3\">Sampling Guide and Additional Information<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Li<\/td><td class=\"column-2\">ICP-MS<\/td><td class=\"column-3\"><ul><li>For air sample: 37 mm MCE cassette. 1-4 L\/min, min 100 liters<\/li><li>Ghost Wipe or Invis-Wipe for surface sampling; 100 cm2 suggested.<\/li><li>Min 2 grams bulk residue.<\/li><\/ul><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Ni, Co, Mn, Al, Ti, P<\/td><td class=\"column-2\">ICP-MS<\/td><td class=\"column-3\"><ul><li>Ghost Wipe or Invis-Wipe for surface sampling; 100 cm2 suggested.<\/li><li>Min 2 grams bulk residue.<\/li><li><em>NIOSH 7300 for air (see current price book)<\/em><\/li><\/ul><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Fluoride<\/td><td class=\"column-2\">IC<\/td><td class=\"column-3\"><ul><li>Alcohol prep wipe for surface sampling; 100 cm2 suggested.<\/li><li>Min 2 grams bulk residue.<\/li><\/ul><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\"><em>Hydrofluoric Acid\/HF<\/em><\/td><td class=\"column-2\">IC<\/td><td class=\"column-3\"><ul><li><em>NIOSH 7906; Area sampling only, not for personal monitoring<\/em><\/li><\/ul><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-52 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e65be8 elementor-widget elementor-widget-text-editor\" data-id=\"2e65be8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Note: It is suggested to start the lithium-ion battery fire residue investigation with lithium as target analyte because it is not a common element in the environment. For a more comprehensive investigation, analysis for additional metals and fluoride\/HF should be added.<\/p><p>Contact John Passero <a href=\"mailto:jpassero@emsl.com\">jpassero@emsl.com<\/a> for pricing.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Lithium-Ion Battery Fire Residues Analysis EMSL Analytical, Inc. provides testing for lithium-ion battery fire residues in the Materials Science Laboratory. The major chemical components in lithium-ion batteries (LIB\u2019s) are: Lithium combined with a metal oxide (for cathode) Lithium + Cobalt [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":5604,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-5653","page","type-page","status-publish","hentry","slug-lithium-ion-battery-fire-residues-analysis","odd_post_id"],"_links":{"self":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/5653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/comments?post=5653"}],"version-history":[{"count":10,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/5653\/revisions"}],"predecessor-version":[{"id":5669,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/5653\/revisions\/5669"}],"up":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/pages\/5604"}],"wp:attachment":[{"href":"https:\/\/laboratorytesting.com\/fr\/wp-json\/wp\/v2\/media?parent=5653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}