{"id":5472,"date":"2026-04-15T09:25:00","date_gmt":"2026-04-15T13:25:00","guid":{"rendered":"https:\/\/laboratorytesting.com\/?page_id=5472"},"modified":"2026-04-21T10:55:26","modified_gmt":"2026-04-21T14:55:26","slug":"lead-hud-guidelines-dust-wipes","status":"publish","type":"page","link":"https:\/\/laboratorytesting.com\/pt\/resources\/lead\/lead-hud-guidelines-dust-wipes\/","title":{"rendered":"Guia de Chumbo HUD para Limpeza de P\u00f3"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"5472\" class=\"elementor elementor-5472\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f0777b3 bg-four-corner-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f0777b3\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4760a46\" data-id=\"4760a46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f2fe9f elementor-widget elementor-widget-heading\" data-id=\"4f2fe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Novo Programa de Subven\u00e7\u00f5es HUD LBPHC\/LHRD de 2017<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13cae54 elementor-widget elementor-widget-image\" data-id=\"13cae54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"426\" src=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lead-hud-guidelines-dust-wipes.jpg\" class=\"attachment-full size-full wp-image-5474\" alt=\"\" srcset=\"https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lead-hud-guidelines-dust-wipes.jpg 1200w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lead-hud-guidelines-dust-wipes-300x107.jpg 300w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lead-hud-guidelines-dust-wipes-1024x364.jpg 1024w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lead-hud-guidelines-dust-wipes-768x273.jpg 768w, https:\/\/laboratorytesting.com\/wp-content\/uploads\/2026\/04\/lead-hud-guidelines-dust-wipes-600x213.jpg 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06f0ed1 elementor-widget elementor-widget-heading\" data-id=\"06f0ed1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">N\u00edveis de a\u00e7\u00e3o para poeira com chumbo: avalia\u00e7\u00e3o de risco e remo\u00e7\u00e3o.<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd28073 elementor-widget elementor-widget-heading\" data-id=\"fd28073\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Introdu\u00e7\u00e3o<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c6595c elementor-widget elementor-widget-text-editor\" data-id=\"3c6595c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Em 16 de fevereiro de 2017, o Departamento de Habita\u00e7\u00e3o e Desenvolvimento Urbano dos EUA (HUD), por meio do Escrit\u00f3rio de Controle de Riscos de Chumbo e Casas Saud\u00e1veis, <strong>(OLHCHH)<\/strong>, emitiu diretrizes pol\u00edticas para estabelecer requisitos novos e mais protetivos para os n\u00edveis de a\u00e7\u00e3o da poeira de chumbo:<\/p><ul><li>Esta orienta\u00e7\u00e3o pol\u00edtica \u00e9 eficaz. <strong>1 de abril de 2017<\/strong>.<\/li><li>Esta orienta\u00e7\u00e3o pol\u00edtica <span style=\"text-decoration: underline;\">aplica-se somente a<\/span> ao seu Controle de Riscos de Tinta \u00e0 Base de Chumbo <strong>(LBPHC)<\/strong> e Demonstra\u00e7\u00e3o de Redu\u00e7\u00e3o de Riscos de Chumbo <strong>(LHRD)<\/strong> programas dos benefici\u00e1rios.<\/li><li>Sim, faz. <span style=\"text-decoration: underline;\">n\u00e3o<\/span> n\u00e3o constituem regulamenta\u00e7\u00e3o sob a regra de Habita\u00e7\u00e3o Segura contra Chumbo do HUD, nem se aplicam ao trabalho realizado sob essa regra.<\/li><li>Sim, faz. <span style=\"text-decoration: underline;\">n\u00e3o<\/span> n\u00e3o se aplicam nem \u00e0 norma da EPA sobre os riscos da tinta \u00e0 base de chumbo, nem \u00e0 sua norma sobre as normas de pr\u00e1ticas de trabalho para a realiza\u00e7\u00e3o de atividades com tinta \u00e0 base de chumbo.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb6ea6e elementor-widget elementor-widget-text-editor\" data-id=\"eb6ea6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Para atender aos novos requisitos da pol\u00edtica do HUD, \u00e9 necess\u00e1rio solicitar aos nossos clientes as seguintes \u00e1reas de limpeza (outros n\u00edveis de a\u00e7\u00e3o do HUD LHC\/HH podem ser atendidos com uma \u00e1rea de limpeza menor):<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-934a5c0 tp-shortcode elementor-widget elementor-widget-shortcode\" data-id=\"934a5c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-41\" class=\"tablepress tablepress-id-41 tp-no-border tp-text-center tp-y-padding-zero tp-head-transparent tp-head-border-bottom-only\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Local de limpeza<\/th><th class=\"column-2\">Nova a\u00e7\u00e3o do HUD<br \/>\nN\u00edveis, \u00b5g\/ft\u00b3.<sup>2<\/sup> (2)<\/th><th class=\"column-3\">\u00c1rea m\u00ednima<\/th><th class=\"column-4\">Sugest\u00e3o EMSL<br \/>\n\u00c1rea<\/th><th class=\"column-5\">Outro HUD (LHC\/HH)<br \/>\nN\u00edveis de a\u00e7\u00e3o, \u00b5g\/ft\u00b2 (3)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Pisos internos (1):<\/td><td class=\"column-2\">10<\/td><td class=\"column-3\">288 pol\u00b2 (2,0 p\u00e9s\u00b2)<\/td><td class=\"column-4\">288 pol\u00b2 (2,0 p\u00e9s\u00b2)<\/td><td class=\"column-5\">40<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Pisos de varanda:<\/td><td class=\"column-2\">40<\/td><td class=\"column-3\">72 pol.\u00b2 (0,5 p\u00e9s\u00b2)<\/td><td class=\"column-4\">144 pol.\u00b2 (1,0 p\u00e9\u00b2)<\/td><td class=\"column-5\">\u2013\u2013<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Peitoris de janela:<\/td><td class=\"column-2\">100<\/td><td class=\"column-3\">28,8 pol\u00b2 (0,2 p\u00e9s\u00b2)<\/td><td class=\"column-4\">72 pol.\u00b2 (0,5 p\u00e9s\u00b2)<\/td><td class=\"column-5\">250<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Calhas de janela:<\/td><td class=\"column-2\">100<\/td><td class=\"column-3\">28,8 pol\u00b2 (0,2 p\u00e9s\u00b2)<\/td><td class=\"column-4\">72 pol.\u00b2 (0,5 p\u00e9s\u00b2)<\/td><td class=\"column-5\">400<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-41 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d298a1 elementor-widget elementor-widget-text-editor\" data-id=\"3d298a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol><li>Os seguintes itens tamb\u00e9m s\u00e3o considerados pisos internos:<ul><li>um piso de garagem anexo a um espa\u00e7o habit\u00e1vel<\/li><li>um piso de varanda externa que foi completamente fechado como parte de um espa\u00e7o habit\u00e1vel<\/li><li>um piso em uma garagem independente usado em parte como espa\u00e7o habit\u00e1vel<\/li><\/ul><\/li><li>Aplic\u00e1vel somente aos programas de subven\u00e7\u00e3o da LBPHC e da LHRD.<\/li><li>Aplic\u00e1vel aos programas de Controle de Riscos de Chumbo (LHC) e Casas Saud\u00e1veis (HH) que recebem subs\u00eddios.<\/li><\/ol><p><strong>Observa\u00e7\u00e3o:<\/strong> As refer\u00eancias acima se aplicam a <strong><span style=\"text-decoration: underline;\">limpeza \u00fanica<\/span><\/strong> An\u00e1lise utilizando FLAA. Se o laborat\u00f3rio for acreditado utilizando ICP-OES, os N\u00edveis de Refer\u00eancia adequados podem ser alcan\u00e7ados com \u00e1reas m\u00ednimas inferiores \u00e0s listadas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>New 2017 HUD LBPHC\/LHRD Grantee Program Dust-Lead Action Levels for Risk Assessment and Clearance Introduction On February 16, 2017, the U.S. Department of Housing and Urban Development (HUD), through the Office of Lead Hazard Control and Healthy Homes (OLHCHH), issued [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":5401,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-5472","page","type-page","status-publish","hentry","slug-lead-hud-guidelines-dust-wipes","even_post_id"],"_links":{"self":[{"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/pages\/5472","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/comments?post=5472"}],"version-history":[{"count":19,"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/pages\/5472\/revisions"}],"predecessor-version":[{"id":5755,"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/pages\/5472\/revisions\/5755"}],"up":[{"embeddable":true,"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/pages\/5401"}],"wp:attachment":[{"href":"https:\/\/laboratorytesting.com\/pt\/wp-json\/wp\/v2\/media?parent=5472"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}