Fire Damage Restoration
and Electronics Industry

TestPurposeMethodMediaFlow RateNotes
Combustion-by Products
ScreeningAnalysis for
combustion-by-products
(Presumptive/Screening)
Light Microscopy,
ASTM D6602-13 (Mod)
Tape lifts; micro-vacuum; grab/
bulk; alcohol prep wipes;
spore trap
PCM, TEM cassette
Spore trap: 15L/min;
max 150 L
PCM/TEM:
0.5-16L/min
min 400 L
Analysis for Char, Ash; Soot/
black carbon presumptive;
Presence/Absence
Level 1Analysis for
combustion-by-products
Light Microscopy,
ASTM D6602-13 (Mod)
Tape lifts; micro-vacuum; grab/
bulk; alcohol prep wipes;
spore trap
PCM, TEM cassette
Spore trap: 15L/min;
max 150 L
PCM/TEM:
0.5-16L/min
min 400 L
Analysis for Char, Ash; Soot/
black carbon presumptive
Level 1 PLUSAnalysis for
combustion-by-products
Light Microscopy,
ASTM D6602-13 (Mod)
Tape lifts; micro-vacuum; grab/
bulk; alcohol prep wipes;
spore trap
PCM, TEM cassette
Spore trap: 15L/min;
max 150 L
PCM/TEM:
0.5-16L/min
min 400 L
Char, Ash; Soot/Black
carbon confirmatory, other
common components of
environmental dust
Level 2Analysis for
combustion-by-products
Light Microscopy;
Electron microscopy
(TEM/EDX)
ASTM D6602-13
Micro-vacuum; grab/bulk;
alcohol prep wipes;
–Char, Ash; Soot/Black
carbon confirmatory
(TEM analysis)
Level 3Analysis of combustion
by-products and other
common components of
environmental dust
Light Microscopy;
Electron microscopy
(TEM/EDX) ASTM
D6602-13
Micro-vacuum; grab/bulk;
alcohol prep wipes
–Char, Ash; Soot/Black
carbon confirmatory, other
common components of
environmental dust;
SEM /EDX of particulate
Level 4Analysis of combustion
by-products and other
common components
of environmental dust,
corrosivity of dust
Light Microscopy;
Electron microscopy
(TEM/EDX; SEM/EDX)
ASTM D6602-13
Micro-vacuum; grab/bulk;
alcohol prep wipes
–Char, Ash; Soot/Black
carbon confirmatory, other
regular components of
environmental dust, SEM/
EDX of particulate, pH of
dust to assess corrosivity
Carbon BlackPresence of carbon black,
soot/black carbon in air
NIOSH 5000,
gravimetric only
37 mm pre-weighed
PVC cassettes
Pump
1-2 liter/minute
30-570 liters
The method is nonspecific.
The presence of any other
particulate in the air being
sampled will be a positive
interference. Information
on any other particulate
materials present should be
assessed.
NIOSH 5000 with TEM/
EDX confirmation
37 mm pre-weighed PVC
cassettes, pump
1-2 liter/minute
30-570 liters
Presence of carbon black
by TEM/EDX is assessed.
Anions Scan: Fluoride,
Chloride, Nitrate,
Nitrite, Bromide, Ortho
Phosphate, Sulfate
Assessment of corrosivity
associated with acids
EPA 300 (Mod)Gauze moistened with DI
water; grab sample/bulk;
micro-vacuum
–Anions by Ion
Chromatography
NIOSH 7903
Air
WW SGT0.2-0.5 liters/min
3-100 Liters
Anions by Ion
Chromatography
pHAssessment of overall
corrosivity
ASTM D4972-13 (mod)Gauze moistened with DI
water; grab sample/bulk;
micro-vacuum
–None
Metals Scan:
Lead (Pb)
Arsenic (As)
Mercury (Hg)
Cadmium (Cd)
Tin (Sn)
Chromium (Cr)
Vanadium (V)
Zinc (Zn)
Manganese (Mn)
Aluminum (Al)
Nickel (Ni)
Titanium (Ti)
Assessment of
metal-based dust
EPA 6010BGauze moistened with DI
water; grab sample/bulk;
micro-vacuum
–Additional element
(metals) can be added
by request for additional
charge.
NIOSH 7300
Air
0.8 um MCE filter, pump1-4 liters/min
250-500 liters
Additional element (metals)
can be added by request for
additional charge.
Polycyclic Aromatic
Hydrocarbons (PAH’s)
Assessment of residual
aromatic hydrocarbons
EPA625/8270CGauze moistened with
acetone/hexane mix or alcohol
prep wipe; grab sample/bulk;
micro-vacuum
–None
NIOSH 5506
Air
37 mm PTFE
XAD-2 Tube, pump
2 liters/min
200-1000 liters
None
Aldehyde scanAssessment of presence
of aldehydes
NIOSH 2016 (Mod)
Air
DNPH treated silica tube
pump
0.03-1.5 liter/min
1-15 liters
None
VOCs (C2-C7)
Normal alkanes (C24-C30)
Benzene
Toluene
Methyl chloride
Naphthalene
Substituted Naphthalene
Substituted Furans
Assessment of volatiles
and semi-volatiles
EPA TO-15 w/library
search
Air
Minican/TO canister<1-24Hr
0.4--6 liters
None

For More Information on Our Lab Testing Services, Pricing, Sampling Guides, or Products:

Subscribe to Our Monthly Email Newsletter for Industry Professionals.

EMSL's EASY TO USE TEST KITS

Trusted by Inspectors, Property Managers, Building Owners, Real Estate and Environmental Professionals

Our test kits offer simple, easy-to-follow instructions that allow both the do-it-yourself or the field professional an added testing service as part of an inspection or prevention strategy. All kits include pre-paid postage and a variety of turnaround options including same-day!

*Lab Fees Required Upon Return For Testing